Quick Menu

LCR Meter / Auto Transformer Test System

RFLCRMeter Model11090-030
  • CE Mark
  • Rohs 2 Compliant
RF LCR Meter
Model 11090-030
  • Measurement parameters:Z、θz、 Y、 θy、 R、 X、G、B、Ls、Lp、Cs、Cp、Rs、Rp、D、Q
  • Test frequencies:100kHz~300MHz
  • Test signal:-40dBm~1dBm
  • Fast measurement:0.5 ms
  • Impedance measurement range:100mΩ~5kΩ
HFLCRMeter  Model11050Series
  • CE Mark
HF LCR Meter 
Model 11050 Series
  • Test frequency: 75kHz~30MHz/1kHz~10MHz/60Hz~5MHz
  • Basic accuracy: 0.1%
  • Measurement time: 7ms
  • Standard RS-232, Handler, and USB storage I/F, optional GPIB, LAN I/F
LCRMeter Model11021/11021-L
  • CE Mark
LCR Meter
Model 11021/11021-L
  • Test frequency: 100, 120, 1k, 10kHz (11021) / 1k, 10k, 40k, 50kHz (11021-L)
  • Basic accuracy: 0.1% (11021) / 0.2% (11021-L)
  • Measurement time: 75ms
  • Standard RS-232 I/F, optional GPIB & Handler I/F
LCRMeter Model11022/11025
  • CE Mark
LCR Meter
Model 11022/11025
  • Test frequency: 50, 60, 100, 120, 1k, 10k, 20k, 40k, 50k, 100kHz
  • Basic accuracy: 0.1%
  • Measurement time: 21ms
  • Standard RS-232, GPIB, and Handler I/F
AutomaticTransformerTester Model13350
  • CE Mark
Automatic Transformer Tester
Model 13350
  • Test frequency: 20Hz~200kHz / 20Hz~1MHz
  • Basic accuracy: 0.1%
  • Optional fixtures for different applications: 20ch scan unit, 80ch scan box, and C.T. test fixture
  • Standard RS-232, USB storage I/F, optional LAN & USB-H I/F
TransformerTestSystem/ComponentAnalyzer Model3250/3252/3302
  • CE Mark
Transformer Test System / Component Analyzer
Model 3250/3252/3302
  • Test frequency: 20Hz~200kHz (3250/3252) / 20Hz~1MHz (3302)
  • Basic accuracy: 0.1%
  • Optional 20ch scan box
  • Standard RS-232, Handler I/F, optional GPIB I/F only for LCR function
BiasCurrentSource Model1320/1320S/1320-10A
  • CE Mark
Bias Current Source
Model 1320/1320S/1320-10A
  • Frequency Response:
    • 1320/1320S/1320-10A: 20Hz~1MHz
  • Output current:
    • 1320-10A: 0.001A~10.00A
    • 1320/1320S: 0.001A~20.00A
  • Directly controlled by LCR meter 11022/11025/3252/3302 (1320/1320S/1320-10A)
  • Standard GPIB and Handler I/F
BiasCurrentTestSystem Model11300
  • CE Mark
Bias Current Test System
Model 11300
  • Frequency response: 20Hz~1MHz
  • Output current: up to 300.0 A by 20.00 A modules
  • Output current accuracy: 3%
  • Windows based software for curve analysis